General
Product Name | Blood Glucose Testing Machine |
---|---|
Function | in the quantitative measurement of glucose in human whole blood taken from the fingertip (capillary) or from the vein (venous) or from the artery (arterial) |
Certification | CE |
Warranty | 1 Year |
After Sales Service | after-sale technical support |
Details
Intended Use | -It is intended for use in the quantitative measurement of glucose in human whole blood taken from the fingertip (capillary) or from the vein (venous) or from the artery (arterial). -It is intended to be used by people with diabetes at home or clinical site as an aid in monitoring the effectiveness of their diabetes control programs. |
---|---|
Test Principle | -A glucose test is based on the measurement of electrical current caused by the reaction of glucose with the FAD glucose dehydrogenase on the electrode of the strip. -The blood or control solution sample is drawn into the tip of the test strip through capillary action. -Glucose in the sample reacts with the FAD glucose dehydrogenase and generates electrons, which produce an electrical current. -The blood glucose meter measures the electrical current and calculates the glucose result. The glucose result is displayed by the meter in the unit of mg/dL or mmol/L. |
Blood Glucose Test Strip | It is intended to be used with blood glucose meter to measure the amount of blood glucose in fresh capillary whole blood or venous blood or arterial blood. The blood glucose test strip used with the blood glucose meter provides a complete test system that is intended for in vitro diagnostic use by people with diabetes. The blood glucose test strip do not require coding. Please refer to the “Performing a Blood Glucose Test” section for complete instructions. |
Features |
|
Specification
Blood volume | 0.8μL |
---|---|
Sample type | Capillary whole bloodyenous whole blood |
Calibration | Plasma equivalent |
Measuring time | 5s |
Meter storage/transportation condition | -20C~55℃ |
Dimension | (103mm (L) x 60mm (W) x 24mm(H)) |
Weight | about 59g |
Power source | 2 AAA alkaline batteries |
Memory | 999 blood glucose measurement results with date and time 200 Control Solution measurement results with date and time |
Operating condition | 10℃~35C≤80% RH |
Construction | Hand-held |
Measurement units | mg/dL or mmol/L |
Measurement range | 20~600 mg/dL or 1.1~33.3mmol/L |
Test condition Temperature | 10℃~40℃ Relative Humidity: 10% ~ 90% RH (non-condensing) Hematocrit:20%~70% Altitude: Up to 10100 feet (3078 meters) Note: Use within specified environmental conditions only. |
Test strip chemical composition | FAD glucose dehydrogenase, potassium ferricyanide, non-reactive ingredients |
Control solution chemical composition | Water, glucose, preservative, dyes, phosphate buffer, viscosity enhancing agents |
Test strip storage condition | 1℃~30℃ 10%~90%RH |
Shelf life | 10 years(estimated by test 7 times per day). During use, user should maintain the product refer to this user manual’s requirements. |