Blood Glucose Testing Machine

  • CE certification
  • Warranty
  • After-sale Service
Share it now !

General

Product Name Blood Glucose Testing Machine
Function in the quantitative measurement of glucose in human whole blood taken from the fingertip (capillary) or
from the vein (venous) or from the artery (arterial)
Certification CE
Warranty 1 Year
After Sales Service after-sale technical support

Details

Intended Use -It is intended for use in the quantitative measurement of glucose in human whole blood taken from the fingertip (capillary) or from the vein (venous) or from the artery (arterial).
-It is intended to be used by people with diabetes at home or clinical site as an aid in monitoring the effectiveness of their diabetes control programs.
Test Principle -A glucose test is based on the measurement of electrical current caused by the reaction of glucose with the FAD glucose dehydrogenase on the electrode of the strip.
-The blood or control solution sample is drawn into the tip of the test strip through capillary action.
-Glucose in the sample reacts with the FAD glucose dehydrogenase and generates electrons, which produce an electrical current.
-The blood glucose meter measures the electrical current and calculates the glucose result. The glucose result is displayed by the meter in the unit of mg/dL or mmol/L.
Blood Glucose Test Strip It is intended to be used with blood glucose meter to measure the amount of blood glucose in fresh capillary whole blood or venous blood or arterial blood. The blood glucose test strip used with the blood glucose meter provides a complete test system that is intended for in vitro diagnostic use by people with diabetes. The blood glucose test strip do not require coding. Please refer to the “Performing a Blood Glucose Test” section for complete instructions.
Features
  • 99.99% gold electrode, a conductivity of 1,400 times than carbon electrode.
  • With superior electrochemical property and extremely strong corrosion resistance.
  • Able to detect the blood sample temperature, HCT and ambient temperature accurately, and automatically correct the result deviations caused by above factors.

Specification

Blood volume 0.8μL
Sample type Capillary whole bloodyenous whole blood
Calibration Plasma equivalent
Measuring time 5s
Meter storage/transportation condition -20C~55℃
Dimension (103mm (L) x 60mm (W) x 24mm(H))
Weight about 59g
Power source 2 AAA alkaline batteries
Memory 999 blood glucose measurement results with
date and time
200 Control Solution measurement results with
date and time
Operating condition 10℃~35C≤80% RH
Construction Hand-held
Measurement units mg/dL or mmol/L
Measurement range 20~600 mg/dL or 1.1~33.3mmol/L
Test condition Temperature 10℃~40℃
Relative Humidity: 10% ~ 90% RH (non-condensing)
Hematocrit:20%~70%
Altitude: Up to 10100 feet (3078 meters)
Note: Use within specified environmental conditions only.
Test strip chemical composition FAD glucose dehydrogenase, potassium ferricyanide,
non-reactive ingredients
Control solution chemical composition Water, glucose, preservative, dyes, phosphate buffer,
viscosity enhancing agents
Test strip storage condition 1℃~30℃ 10%~90%RH
Shelf life 10 years(estimated by test 7 times per day).
During use, user should maintain the product
refer to this user manual’s requirements.

 

 

#